TECHNICAL SPECIFICATION

Cooling power

36KW (at ambient temperature 50 °C; indoor climate 25 °C / 40 % RH, FA=0)

Supply air flow

5400 m3/h at 300 Pa

Fresh air flow

2500  m3/h

Input power

3 x 415 V, 50 Hz, 20 kW (at 50 °C)

Maximum ambient:

57 °C

Refrigerant

R-407C

Heating

Tubular heating elements, 8 kW

Heat exchangers

Copper tubes in pre-coated aluminium fins

Filters

Fresh air and mixed air filters, access from coach roof

Scope of supply

HVAC unit, anti-vibration mounts, SA & FA bellows, microcontroller, display and operating panel, PC service software

Mass (HVAC unit)

725 kg




 