TECHNICAL SPECIFICATION

Cooling power

25 kW (at ambient temperature 50 °C; indoor climate 25 °C / 40 % RH, FA=0)

Supply air flow

4000 m3/h at 200 Pa

Fresh air flow

1560  m3/h (adjustable with motorised FA/RA dampers)

Input power

3 x 415 V, 50 Hz, 13 kW (at 50 °C)

Maximum ambient:

57 °C

Refrigerant

R-22

Heating

Tubular heating elements, 6 kW

Dehumidification

Dehumidification mode controlled by hygrostat

Heat exchangers

Copper tubes in pre-coated aluminium fins

Filters

Fresh air and mixed air filters, access from the coach roof

Scope of supply

HVAC unit, anti-vibration mounts, SA & FA bellows, microcontroller unit, display & operating panel

Mass (HVAC unit)

610 kg





 
Home         Profile          Quality         Cleints         Enquiry         Media        Contact us      Jobs in Sidwal © Copyright Reserved to Sidwal