DIVISION
 
INDIAN RAILWAYS
METRO RAIL
DEFENCE
BUS AC
TELECOM & IT
WATER COOLER
 
METRE GAUGE
TECHNICAL SPECIFICATION

Cooling power

17,5 kW (at ambient temperature 50 °C; indoor climate 25 °C / 40 % RH, FA=0)

Supply air flow

4000 m3/h at 200 Pa

Fresh air flow

1560  m3/h

Input power

3 x 415 V, 50 Hz, 8,4 kVA (at 50 °C)

Maximum ambient:

57 °C

Refrigerant

R-22

Heating

Tubular heating elements, 6 kW

Dehumidification

Dehumidification mode controlled by hygrostat

Heat exchangers

Copper tubes in tinned copper fins

Filters

Fresh air and mixed air filters, access from passenger area

Scope of supply

HVAC unit, anti-vibration mounts, SA & FA bellows, electrical control panel, set of connecting power & control cables

Mass (HVAC unit)

530 kg





 