TECHNICAL SPECIFICATION

Cooling power

25 KW (at ambient temperature 50 °C; indoor climate 25 °C / 40 % RH, FA=0)

Supply air flow

4000 m3/h at 200 Pa

Fresh air flow

1050  m3/h

Input power

3 x 415 V, 50 Hz, 13 kW (at 50 °C)

Maximum ambient:

57 °C

Refrigerant

R-22 or R-407C

Heating

Tubular heating elements, 6 kW; Optional: reverse cycle heating

Heat exchangers

Copper tubes in tinned copper fins

Filters

Fresh air and mixed air filters, access from passenger area

Scope of supply

HVAC unit, anti-vibration mounts, SA & FA bellows, electrical control panel with electronic thermostat

Mass (HVAC unit)

700 kg




 